Capacity VA 1000  VA  /  800  W
Input
Power Factor ≥0.98
Phase Single  phase  &  Ground
Rated Voltage 220  VAC
Voltage Range 115  VAC  -  295  VAC
Frequency Range 45  ~  55  Hz  or  55  ~  65  Hz  ±  0.5  Hz  auto  sensing
Bypass Voltage 186  VAC  -  252  VAC
ECO Range 220  VAC  -  240  VAC
Current Harmonic ≥7%    (100%    non-lineer  load)
Output
Crest Factor 3:1
Power Factor 0.8
Overload Capacity Battery  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  cut  off  and  alarm,
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,  cut  off  and  alarm
Utility  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  transfer  to  bypass  and  alarm
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,transfer  to  bypass  and  alarm
Phase Single  phase  &  Ground
Rated Voltage 200  /  208  /  220  /  230  /  240  VAC  (optional)
Voltage Precision ±  0.2%
Output Frequency Utility  Mode:  Fallow  Utility,  Battery  Mode:  (50/60  ±  0.2)  Hz
Transfer Time (Utility  -  Battery)  =  0  ms,  (Utility  -  Battery)  <  4  ms,  (Utility  -  ECO)  <  10ms,  (Battery  -  ECO)  <  10  ms  
Efficency Utility  Mode  87%
Battery  Mode  85%
THD ≤  3%  (100%  lineer  load)
≤  5%  (100%  non-lineer  load)
Battery
Type 12  V  /  9  AH  Free  maintenance  High-Rate  Sealed  Lead  Acid  Battery  (Standard)
Voltage 24  VDC
Battery Configuration 2x12  V  /  9  AH
Backup Time Full  load  ≥  5  min  (Standard),  Long  time  unit  depends  on  the  capacity  of  battery
Charge Current (A) 1  A
Communication Interface RS232.  Optional  (USB  port,  USB  card,  SNMP  card,  Dry  contact  card)
Environment
Temperature 0  șC  ~  40  șC
Humidity 0~95%    (Non-condensing)
Storage Temperature -25  șC  ~  55  șC
Operation Height <1500  m
Other
Unit Dimensions WxDxH (mm) 440x380x86.5
Weight (kg) 12/14.5
Industry Standard YD/T  1095-2000
Capacity VA 1000  VA  /  800  W
Input
Power Factor ≥0.98
Phase Single  phase  &  Ground
Rated Voltage 220  VAC
Voltage Range 115  VAC  -  295  VAC
Frequency Range 45  ~  55  Hz  or  55  ~  65  Hz  ±  0.5  Hz  auto  sensing
Bypass Voltage 186  VAC  -  252  VAC
ECO Range 220  VAC  -  240  VAC
Current Harmonic ≥7%    (100%    non-lineer  load)
Output
Crest Factor 3:1
Power Factor 0.8
Overload Capacity Battery  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  cut  off  and  alarm,
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,  cut  off  and  alarm
Utility  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  transfer  to  bypass  and  alarm
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,transfer  to  bypass  

and  alarm
Phase Single  phase  &  Ground
Rated Voltage 200  /  208  /  220  /  230  /  240  VAC  (optional)
Voltage Precision ±  0.2%
Output Frequency Utility  Mode:  Fallow  Utility,  Battery  Mode:  (50/60  ±  0.2)  Hz
Transfer Time (Utility  -  Battery)  =  0  ms,  (Utility  -  Battery)  <  4  ms,  (Utility  -  ECO)  <  10ms,  (Battery  -  ECO)  <  10  ms  
Efficency Utility  Mode  87%
Battery  Mode  85%
THD ≤  3%  (100%  lineer  load)
≤  5%  (100%  non-lineer  load)
Battery
Type 12  V  /  9  AH  Free  maintenance  High-Rate  Sealed  Lead  Acid  Battery  (Standard)
Voltage 24  VDC
Battery Configuration 2x12  V  /  9  AH
Backup Time Full  load  ≥  5  min  (Standard),  Long  time  unit  depends  on  the  capacity  of  battery
Charge Current (A) 7  A
Communication Interface RS232.  Optional  (USB  port,  USB  card,  SNMP  card,  Dry  contact  card)
Environment
Temperature 0  șC  ~  40  șC
Humidity 0~95%    (Non-condensing)
Storage Temperature -25  șC  ~  55  șC
Operation Height <1500  m
Other
Unit Dimensions WxDxH (mm) 440x380x86.5
Weight (kg) 7/9.5
Industry Standard YD/T  1095-2000
Capacity VA 2000  VA  /  1600  W
Input
Power Factor ≥0.98
Phase Single  phase  &  Ground
Rated Voltage 220  VAC
Voltage Range 115  VAC  -  295  VAC
Frequency Range 45  ~  55  Hz  or  55  ~  65  Hz  ±  0.5  Hz  auto  sensing
Bypass Voltage 186  VAC  -  252  VAC
ECO Range 220  VAC  -  240  VAC
Current Harmonic ≥7%    (100%    non-lineer  load)
Output
Crest Factor 3:1
Power Factor 0.8
Overload Capacity Battery  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  cut  off  and  alarm,
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,  cut  off  and  alarm
Utility  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  transfer  to  bypass  and  alarm
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,transfer  to  bypass  

and  alarm
Phase Single  phase  &  Ground
Rated Voltage 200  /  208  /  220  /  230  /  240  VAC  (optional)
Voltage Precision ±  0.2%
Output Frequency Utility  Mode:  Fallow  Utility,  Battery  Mode:  (50/60  ±  0.2)  Hz
Transfer Time (Utility  -  Battery)  =  0  ms,  (Utility  -  Battery)  <  4  ms,  (Utility  -  ECO)  <  10ms,  (Battery  -  ECO)  <  10  ms  
Efficency Utility  Mode  88%
Battery  Mode  85%
THD ≤  3%  (100%  lineer  load)
≤  5%  (100%  non-lineer  load)
Battery
Type 12  V  /  9  AH  Free  maintenance  High-Rate  Sealed  Lead  Acid  Battery  (Standard)
Voltage 48  VDC
Battery Configuration 4x12  V  /  9  AH
Backup Time Full  load  ≥  5  min  (Standard),  Long  time  unit  depends  on  the  capacity  of  battery
Charge Current (A) 1  A
Communication Interface RS232.  Optional  (USB  port,  USB  card,  SNMP  card,  Dry  contact  card)
Environment
Temperature 0  șC  ~  40  șC
Humidity 0~95%    (Non-condensing)
Storage Temperature -25  șC  ~  55  șC
Operation Height <1500  m
Other
Unit Dimensions WxDxH (mm) 440x520x131
Weight (kg) 21.5/24.5
Industry Standard YD/T  1095-2000
Capacity VA 2000  VA  /  1600  W
Input
Power Factor ≥0.98
Phase Single  phase  &  Ground
Rated Voltage 220  VAC
Voltage Range 115  VAC  -  295  VAC
Frequency Range 45  ~  55  Hz  or  55  ~  65  Hz  ±  0.5  Hz  auto  sensing
Bypass Voltage 186  VAC  -  252  VAC
ECO Range 220  VAC  -  240  VAC
Current Harmonic ≥7%    (100%    non-lineer  load)
Output
Crest Factor 3:1
Power Factor 0.8
Overload Capacity Battery  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  cut  off  and  alarm,
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,  cut  off  and  alarm
Utility  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  transfer  to  bypass  and  alarm
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,transfer  to  bypass  

and  alarm
Phase Single  phase  &  Ground
Rated Voltage 200  /  208  /  220  /  230  /  240  VAC  (optional)
Voltage Precision ±  0.2%
Output Frequency Utility  Mode:  Fallow  Utility,  Battery  Mode:  (50/60  ±  0.2)  Hz
Transfer Time (Utility  -  Battery)  =  0  ms,  (Utility  -  Battery)  <  4  ms,  (Utility  -  ECO)  <  10ms,  (Battery  -  ECO)  <  10  ms  
Efficency Utility  Mode  88%
Battery  Mode  85%
THD ≤  3%  (100%  lineer  load)
≤  5%  (100%  non-lineer  load)
Battery
Type 12  V  /  9  AH  Free  maintenance  High-Rate  Sealed  Lead  Acid  Battery  (Standard)
Voltage 48  VDC
Battery Configuration 4x12  V  /  9  AH
Backup Time Full  load  ≥  5  min  (Standard),  Long  time  unit  depends  on  the  capacity  of  battery
Charge Current (A) 7  A
Communication Interface RS232.  Optional  (USB  port,  USB  card,  SNMP  card,  Dry  contact  card)
Environment
Temperature 0  șC  ~  40  șC
Humidity 0~95%    (Non-condensing)
Storage Temperature -25  șC  ~  55  șC
Operation Height <1500  m
Other
Unit Dimensions WxDxH (mm) 440x520x131
Weight (kg) 11.5/14.3
Industry Standard YD/T  1095-2000
Capacity VA 3000  VA  /  2400  W
Input
Power Factor ≥0.98
Phase Single  phase  &  Ground
Rated Voltage 220  VAC
Voltage Range 115  VAC  -  295  VAC
Frequency Range 45  ~  55  Hz  or  55  ~  65  Hz  ±  0.5  Hz  auto  sensing
Bypass Voltage 186  VAC  -  252  VAC
ECO Range 220  VAC  -  240  VAC
Current Harmonic ≥7%    (100%    non-lineer  load)
Output
Crest Factor 3:1
Power Factor 0.8
Overload Capacity Battery  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  cut  off  and  alarm,
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,  cut  off  and  alarm
Utility  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  transfer  to  bypass  and  alarm
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,transfer  to  bypass  

and  alarm
Phase Single  phase  &  Ground
Rated Voltage 200  /  208  /  220  /  230  /  240  VAC  (optional)
Voltage Precision ±  0.2%
Output Frequency Utility  Mode:  Fallow  Utility,  Battery  Mode:  (50/60  ±  0.2)  Hz
Transfer Time (Utility  -  Battery)  =  0  ms,  (Utility  -  Battery)  <  4  ms,  (Utility  -  ECO)  <  10ms,  (Battery  -  ECO)  <  10  ms  
Efficency Utility  Mode  88%
Battery  Mode  85%
THD ≤  3%  (100%  lineer  load)
≤  5%  (100%  non-lineer  load)
Battery
Type 12  V  /  9  AH  Free  maintenance  High-Rate  Sealed  Lead  Acid  Battery  (Standard)
Voltage 72  VDC
Battery Configuration 6x12  V  /  9  AH
Backup Time Full  load  ≥  5  min  (Standard),  Long  time  unit  depends  on  the  capacity  of  battery
Charge Current (A) 1  A
Communication Interface RS232.  Optional  (USB  port,  USB  card,  SNMP  card,  Dry  contact  card)
Environment
Temperature 0  șC  ~  40  șC
Humidity 0~95%    (Non-condensing)
Storage Temperature -25  șC  ~  55  șC
Operation Height <1500  m
Other
Unit Dimensions WxDxH (mm) 440x520x131
Weight (kg) 26/28.8
Industry Standard YD/T  1095-2000
Capacity VA 3000  VA  /  2400  W
Input
Power Factor ≥0.98
Phase Single  phase  &  Ground
Rated Voltage 220  VAC
Voltage Range 115  VAC  -  295  VAC
Frequency Range 45  ~  55  Hz  or  55  ~  65  Hz  ±  0.5  Hz  auto  sensing
Bypass Voltage 186  VAC  -  252  VAC
ECO Range 220  VAC  -  240  VAC
Current Harmonic ≥7%    (100%    non-lineer  load)
Output
Crest Factor 3:1
Power Factor 0.8
Overload Capacity Battery  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  cut  off  and  alarm,
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,  cut  off  and  alarm
Utility  Mode:
108%  ±  5%  -  150%  ±  5%  exceed  30s,  transfer  to  bypass  and  alarm
150%  ±  5%  -  200%  ±  5%  exceed  300  ms,transfer  to  bypass  

and  alarm
Phase Single  phase  &  Ground
Rated Voltage 200  /  208  /  220  /  230  /  240  VAC  (optional)
Voltage Precision ±  0.2%
Output Frequency Utility  Mode:  Fallow  Utility,  Battery  Mode:  (50/60  ±  0.2)  Hz
Transfer Time (Utility  -  Battery)  =  0  ms,  (Utility  -  Battery)  <  4  ms,  (Utility  -  ECO)  <  10ms,  (Battery  -  ECO)  <  10  ms  
Efficency Utility  Mode  88%
Battery  Mode  85%
THD ≤  3%  (100%  lineer  load)
≤  5%  (100%  non-lineer  load)
Battery
Type 12  V  /  9  AH  Free  maintenance  High-Rate  Sealed  Lead  Acid  Battery  (Standard)
Voltage 72  VDC
Battery Configuration 6x12  V  /  9  AH
Backup Time Full  load  ≥  5  min  (Standard),  Long  time  unit  depends  on  the  capacity  of  battery
Charge Current (A) 7  A
Communication Interface RS232.  Optional  (USB  port,  USB  card,  SNMP  card,  Dry  contact  card)
Environment
Temperature 0  șC  ~  40  șC
Humidity 0~95%    (Non-condensing)
Storage Temperature -25  șC  ~  55  șC
Operation Height <1500  m
Other
Unit Dimensions WxDxH (mm) 440x520x131
Weight (kg) 11.7/14.5
Industry Standard YD/T  1095-2000