Products
 
Online UPS
Modular UPS
Dynamic UPS
Line Interactive UPS
Inverter
Voltage Regulator
Renewable Energy Systems
Batteries
Rectifiers
Frequency Converter
19' Rack Cabinet
Accessories
 
   
   
  Home | Products   | Powerpack Plus Series 5-15kVA UPS
 
1/1 Phase Online Ups, 5-15kVA

High frequency and double conversion on-line technology
Pure sine wave form THD< 3%
Full digitized microprocessor control
Advanced PFC technology
Wide input voltage range
UPS Start up without battery
LCD Display
Cold start function
Advanced Battery Management
Automatic battery charge in UPS off mode
Lightning and surge protection
Short circuit and overload protection
Epo function (optional)
EMI/RFI Filter
Fan speed auto control when loads varies
Network/fax/modem surge protection
Optional extension battery pack
Battery voltage display
Load capacity display
Smart RS232 communication with monitoring software
Optional SNMP Card slot
CE, ISO9001 and TSEK certificates
   
  Technical Features
  tabmenu
Capacity VA 3  kVA
Input
Voltage Range 180  -  260  VAC  or    90-130  VAC
Frequency 50/60  Hz  ±  5%  Hz  auto  sensing
Phase Single  phase  +  GND
Max. Input Current (110V) 48  A
Max. Input Current (220V) 14  A
Output
Crest Factor 3:1(max)
Short Circuit Protection Current  limit,  turn  off  automatically,  switch  protect
Voltage Range 220  VAC  ±  1%  or  110  VAC  ±  1%  
Power Factor 0.8
Frequency Range 50  Hz  /  60  Hz  ±  0.5%
Overload Capacity >110%,  30s  turn  to  bypass  mode
>150%,  300ms  turn  to  bypass  mode
Transfer Time 0  ms
THD (lineer load) <3%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Efficency ≥87%
Battery
Charge Current (A) 4,2  A  -  7,5  A
Model 12V  sealed  lead  acid  maintenance  free
DC Voltage 48  VDC  (192  V  optional)
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Temperature 0~40℃
Humidity 0%~95%  (non-condensing)
Acoustic Noise <55dB
Operation Height <1500m
Protection IEEE527B  Surge  Protection  ,    FCC,  A  Noise
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication Low  battery,  online,  inverter,  bypass,  abnormal
Other
Weight (kg) 75  kg
Packing WxDxH (mm) 320x620x730
Capacity VA 5  kVA
Input
Voltage Range 180  -  260  VAC  or    90-130  VAC
Frequency 50/60  Hz  ±  5%  Hz  auto  sensing
Phase Single  phase  +  GND
Max. Input Current (110V) 28  A
Max. Input Current (220V) 24  A
Output
Crest Factor 3:1(max)
Short Circuit Protection Current  limit,  turn  off  automatically,  switch  protect
Voltage Range 220  VAC  ±  1%  or  110  VAC  ±  1%  
Power Factor 0.8
Frequency Range 50  Hz  /  60  Hz  ±  0.5%
Overload Capacity >110%,  30s  turn  to  bypass  mode
>150%,  300ms  turn  to  bypass  mode
Transfer Time 0  ms
THD (lineer load) <3%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Efficency ≥87%
Battery
Charge Current (A) 4,2  A  -  7,5  A
Model 12V  sealed  lead  acid  maintenance  free
DC Voltage 192  VDC
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Temperature 0~40℃
Humidity 0%~95%  (non-condensing)
Acoustic Noise <55dB
Operation Height <1500m
Protection IEEE527B  Surge  Protection  ,    FCC,  A  Noise
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication Low  battery,  online,  inverter,  bypass,  abnormal
Other
Weight (kg) 65  kg
Packing WxDxH (mm) 350x725x810
Capacity VA 6,25  kVA
Input
Voltage Range 180  -  260  VAC  or    90-130  VAC
Frequency 50/60  Hz  ±  5%  Hz  auto  sensing
Phase Single  phase  +  GND
Max. Input Current (110V) 68  A
Max. Input Current (220V) 34  A
Output
Crest Factor 3:1(max)
Short Circuit Protection Current  limit,  turn  off  automatically,  switch  protect
Voltage Range 220  VAC  ±  1%  or  110  VAC  ±  1%  
Power Factor 0.8
Frequency Range 50  Hz  /  60  Hz  ±  0.5%
Overload Capacity >110%,  30s  turn  to  bypass  mode
>150%,  300ms  turn  to  bypass  mode
Transfer Time 0  ms
THD (lineer load) <3%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Efficency ≥87%
Battery
Charge Current (A) 4,2  A  -  7,5  A
Model 12V  sealed  lead  acid  maintenance  free
DC Voltage 192  VDC
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Temperature 0~40℃
Humidity 0%~95%  (non-condensing)
Acoustic Noise <55dB
Operation Height <1500m
Protection IEEE527B  Surge  Protection  ,    FCC,  A  Noise
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication Low  battery,  online,  inverter,  bypass,  abnormal
Other
Weight (kg) 69  kg
Packing WxDxH (mm) 350x725x810
Capacity VA 7,5  kVA
Input
Voltage Range 180  -  260  VAC  or    90-130  VAC
Frequency 50/60  Hz  ±  5%  Hz  auto  sensing
Phase Single  phase  +  GND
Max. Input Current (110V) 90  A
Max. Input Current (220V) 45  A
Output
Crest Factor 3:1(max)
Short Circuit Protection Current  limit,  turn  off  automatically,  switch  protect
Voltage Range 220  VAC  ±  1%  or  110  VAC  ±  1%  
Power Factor 0.8
Frequency Range 50  Hz  /  60  Hz  ±  0.5%
Overload Capacity >110%,  30s  turn  to  bypass  mode
>150%,  300ms  turn  to  bypass  mode
Transfer Time 0  ms
THD (lineer load) <3%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Efficency ≥87%
Battery
Charge Current (A) 4,2  A  -  7,5  A
Model 12V  sealed  lead  acid  maintenance  free
DC Voltage 192  VDC
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Temperature 0~40℃
Humidity 0%~95%  (non-condensing)
Acoustic Noise <55dB
Operation Height <1500m
Protection IEEE527B  Surge  Protection  ,    FCC,  A  Noise
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication Low  battery,  online,  inverter,  bypass,  abnormal
Other
Weight (kg) 92  kg
Packing WxDxH (mm) 350x725x810
Capacity VA 10  kVA
Input
Voltage Range 180  -  260  VAC  or    90-130  VAC
Frequency 50/60  Hz  ±  5%  Hz  auto  sensing
Phase Single  phase  +  GND
Max. Input Current (110V) 112  A
Max. Input Current (220V) 56  A
Output
Crest Factor 3:1(max)
Short Circuit Protection Current  limit,  turn  off  automatically,  switch  protect
Voltage Range 220  VAC  ±  1%  or  110  VAC  ±  1%  
Power Factor 0.8
Frequency Range 50  Hz  /  60  Hz  ±  0.5%
Overload Capacity >110%,  30s  turn  to  bypass  mode
>150%,  300ms  turn  to  bypass  mode
Transfer Time 0  ms
THD (lineer load) <3%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Efficency ≥87%
Battery
Charge Current (A) 4,2  A  -  7,5  A
Model 12V  sealed  lead  acid  maintenance  free
DC Voltage 192  VDC
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Temperature 0~40℃
Humidity 0%~95%  (non-condensing)
Acoustic Noise <55dB
Operation Height <1500m
Protection IEEE527B  Surge  Protection  ,    FCC,  A  Noise
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication Low  battery,  online,  inverter,  bypass,  abnormal
Other
Weight (kg) 100  kg
Packing WxDxH (mm) 470x765x916
Capacity VA 12,5  kVA
Input
Voltage Range 180  -  260  VAC  or    90-130  VAC
Frequency 50/60  Hz  ±  5%  Hz  auto  sensing
Phase Single  phase  +  GND
Max. Input Current (110V) 136  A
Max. Input Current (220V) 68  A
Output
Crest Factor 3:1(max)
Short Circuit Protection Current  limit,  turn  off  automatically,  switch  protect
Voltage Range 220  VAC  ±  1%  or  110  VAC  ±  1%  
Power Factor 0.8
Frequency Range 50  Hz  /  60  Hz  ±  0.5%
Overload Capacity >110%,  30s  turn  to  bypass  mode
>150%,  300ms  turn  to  bypass  mode
Transfer Time 0  ms
THD (lineer load) <3%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Efficency ≥87%
Battery
Charge Current (A) 4,2  A  -  7,5  A
Model 12V  sealed  lead  acid  maintenance  free
DC Voltage 192  VDC
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Temperature 0~40℃
Humidity 0%~95%  (non-condensing)
Acoustic Noise <55dB
Operation Height <1500m
Protection IEEE527B  Surge  Protection  ,    FCC,  A  Noise
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication Low  battery,  online,  inverter,  bypass,  abnormal
Other
Weight (kg) 115  kg
Packing WxDxH (mm) 470x765x916
Capacity VA 15  kVA
Input
Voltage Range 180  -  260  VAC  or    90-130  VAC
Frequency 50/60  Hz  ±  5%  Hz  auto  sensing
Phase Single  phase  +  GND
Max. Input Current (110V) 168  A
Max. Input Current (220V) 84  A
Output
Crest Factor 3:1(max)
Short Circuit Protection Current  limit,  turn  off  automatically,  switch  protect
Voltage Range 220  VAC  ±  1%  or  110  VAC  ±  1%  
Power Factor 0.8
Frequency Range 50  Hz  /  60  Hz  ±  0.5%
Overload Capacity >110%,  30s  turn  to  bypass  mode
>150%,  300ms  turn  to  bypass  mode
Transfer Time 0  ms
THD (lineer load) <3%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Efficency ≥87%
Battery
Charge Current (A) 4,2  A  -  7,5  A
Model 12V  sealed  lead  acid  maintenance  free
DC Voltage 192  VDC
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Temperature 0~40℃
Humidity 0%~95%  (non-condensing)
Acoustic Noise <55dB
Operation Height <1500m
Protection IEEE527B  Surge  Protection  ,    FCC,  A  Noise
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication Low  battery,  online,  inverter,  bypass,  abnormal
Other
Weight (kg) 120  kg
Packing WxDxH (mm) 470x765x916
  Product Catalog