1/1 Phase Online Ups 6-10kVA

High frequency and double conversion on-line technology
Pure sine wave form THD< 3%
Full digitized microprocessor control
Advanced PFC technology
Wide input voltage range
UPS Start up without battery
LCD Display
Paralel operation up to 3 units
Rackmount case option
Cold start function
Advanced Battery Management
Automatic battery charge in UPS off mode
Lightning and surge protection
Short circuit and overload protection
Epo function (optional)
EMI/RFI Filter
Fan speed auto control when loads varies
Network/fax/modem surge protection
Optional extension battery pack
Battery voltage display
Load capacity display
Smart RS232 communication with monitoring software
Optional SNMP Card slot
CE, ISO9001 and TSEK certificates
   
  Technical Features
  tabmenu
Capacity VA 6  kVA  /  4.2  kW
Input
Voltage Range 176  ±  5  VAC  ~  276  ±  5  VAC
Frequency 46  ~  54  Hz  ±  0.5  Hz  or  56  ~  64  Hz  ±  0.5  Hz  auto  sensing
Power Factor ≥0.98
Phase Single  phase
Output
Crest Factor 3:1  (max)
Short Circuit Protection 5  cycles  turn  off  inverter,  no  transfer  to  bypass,  provide  alarm  (AC  mode)
5  cycles  turn  off  inverter,  provide  alarm  (battery  mode)
Input  fuse  blown  or  breaker  action  (bypass  mode)
Frequency Range 50  Hz  /  60  Hz  ±  0.2%  (battery  mode)
Overload Capacity 105%  ~  130%,  10  min  turn  to  bypass  mode;  >130%  1  s  turn  to  bypass  mode    
Phase Single  phase
Transfer Time AC  Mode  and  Battery  Mode  0  ms
Efficency ≥88%
Voltage Range 220  VAC  ±  1%
THD (lineer load) <  2%
THD (non-lineer load) <  6%
Waveform Pure  sine  wave
Battery
Battery Configuration 20x12  V  /  7  AH
Model 12  V  sealed  lead  acid  maintenance  free
DC Voltage 240  VDC
Backup Time (half load) 20  min
Backup Time (full load) 10  min
Charge Current (standart unit) 1  A
Charge Current (long time unit) 5  A  -  7  A
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232;  SNMP  (optional)
Environment
Noise Level <55  dB
Temperature 0℃    ~    40℃
Humidity 0%  ~  95%    (non-condensing)
Storage Temperature 0℃    ~    40℃
Operation Height <1500  m
Indication
LCD Indication 1.  Input  voltage  /  frequency,  battery  voltage,  output  voltage  /  frequency,  load  watt    /  VA    value  and  percent,  inverter  temperature
2.  Operation  mode  such  as  "on  line",  "on  batt"    or  "bypass"
LED Indication 1.  Green  LED  for  normal  operation
2.  Yellow  LED  for  warning  operation
3.  Red  LED  for  abnormal  operation
Parallel Port Parallel  availability  for  redundancy  and  load  sharing  up  to  three  units
Other
Dimension (WxDxH) mm 270x570x720
Standard Unit Net/Gross Weight 89/104  kg
Long Time Unit Net/Gross Weight 34/48  kg
Packing WxDxH (mm) 370x670x940
Capacity VA 6KVA/4.2KW
Input
Voltage Range 176  ±  5  VAC  ~  276  ±  5  VAC
Frequency 46  ~  54  Hz  ±  0.5  Hz  or  56  ~  64  Hz  ±  0.5  Hz  auto  sensing
Power Factor ≥0.98
Phase Single  phase
Output
Crest Factor 3:1  (max)
Short Circuit Protection 5  cycles  turn  off  inverter,  no  transfer  to  bypass,  provide  alarm  (AC  mode)
5  cycles  turn  off  inverter,  provide  alarm  (battery  mode)
Input  fuse  blown  or  breaker  action  (bypass  mode)
Frequency Range 50  Hz  /  60  Hz  ±  0.2%  (battery  mode)
Overload Capacity 105%  ~  130%,  10  min  turn  to  bypass  mode;  >130%  1  s  turn  to  bypass  mode    
Phase Single  phase
Transfer Time AC  Mode  and  Battery  Mode  0  ms
Efficency ≥88%
Voltage Range 220  VAC  ±  1%
THD (lineer load) <  2%
THD (non-lineer load) <  6%
Waveform Pure  sine  wave
Battery
Battery Configuration 20x12  V  /  7  AH
Model 12  V  sealed  lead  acid  maintenance  free
DC Voltage 240  VDC
Backup Time (half load) N/A
Backup Time (full load) N/A
Charge Current (standart unit) 1  A
Charge Current (long time unit) 5  A  -  7  A
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232;  SNMP  (optional)
Environment
Noise Level <55  dB
Temperature 0℃    ~    40℃
Humidity 0%  ~  95%    (non-condensing)
Storage Temperature 0℃    ~    40℃
Operation Height <1500  m
Indication
LCD Indication 1.  Input  voltage  /  frequency,  battery  voltage,  output  voltage  /  frequency,  load  watt    /  VA    value  and  percent,  inverter  temperature
2.  Operation  mode  such  as  "on  line",  "on  batt"    or  "bypass"
LED Indication 1.  Green  LED  for  normal  operation
2.  Yellow  LED  for  warning  operation
3.  Red  LED  for  abnormal  operation
Parallel Port Parallel  availability  for  redundancy  and  load  sharing  up  to  three  units
Other
Dimension (WxDxH) mm 440x656x176
Standard Unit Net/Gross Weight N/A
Long Time Unit Net/Gross Weight 22/25  kg
Packing WxDxH (mm) 580x790x336
Capacity VA 10  kVA/  7  kW
Input
Voltage Range 176  ±  5  VAC  ~  276  ±  5  VAC
Frequency 46  ~  54  Hz  ±  0.5  Hz  or  56  ~  64  Hz  ±  0.5  Hz  auto  sensing
Power Factor ≥0.98
Phase Single  phase
Output
Crest Factor 3:1  (max)
Short Circuit Protection 5  cycles  turn  off  inverter,  no  transfer  to  bypass,  provide  alarm  (AC  mode)
5  cycles  turn  off  inverter,  provide  alarm  (battery  mode)
Input  fuse  blown  or  breaker  action  (bypass  mode)
Frequency Range 50  Hz  /  60  Hz  ±  0.2%  (battery  mode)
Overload Capacity 105%  ~  130%,  10  min  turn  to  bypass  mode;  >130%  1  s  turn  to  bypass  mode    
Phase Single  phase
Transfer Time AC  Mode  and  Battery  Mode  0  ms
Efficency ≥88%
Voltage Range 220  VAC  ±  1%
THD (lineer load) <  2%
THD (non-lineer load) <  6%
Waveform Pure  sine  wave
Battery
Battery Configuration 20x12  V  /  7  AH
Model 12  V  sealed  lead  acid  maintenance  free
DC Voltage 240  VDC
Backup Time (half load) 13  min
Backup Time (full load) 8  min
Charge Current (standart unit) 1  A
Charge Current (long time unit) 5  A  -  7  A
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232;  SNMP  (optional)
Environment
Noise Level <55  dB
Temperature 0℃    ~    40℃
Humidity 0%  ~  95%    (non-condensing)
Storage Temperature 0℃    ~    40℃
Operation Height <1500  m
Indication
LCD Indication 1.  Input  voltage  /  frequency,  battery  voltage,  output  voltage  /  frequency,  load  watt    /  VA    value  and  percent,  inverter  temperature
2.  Operation  mode  such  as  "on  line",  "on  batt"    or  "bypass"
LED Indication 1.  Green  LED  for  normal  operation
2.  Yellow  LED  for  warning  operation
3.  Red  LED  for  abnormal  operation
Parallel Port Parallel  availability  for  redundancy  and  load  sharing  up  to  three  units
Other
Dimension (WxDxH) mm 270x570x720
Standard Unit Net/Gross Weight 92/107  kg
Long Time Unit Net/Gross Weight 36/51  kg
Packing WxDxH (mm) 370x670x940
Capacity VA 10  kVA/  7  kW
Input
Voltage Range 176  ±  5  VAC  ~  276  ±  5  VAC
Frequency 46  ~  54  Hz  ±  0.5  Hz  or  56  ~  64  Hz  ±  0.5  Hz  auto  sensing
Power Factor ≥0.98
Phase Single  phase
Output
Crest Factor 3:1  (max)
Short Circuit Protection 5  cycles  turn  off  inverter,  no  transfer  to  bypass,  provide  alarm  (AC  mode)
5  cycles  turn  off  inverter,  provide  alarm  (battery  mode)
Input  fuse  blown  or  breaker  action  (bypass  mode)
Frequency Range 50  Hz  /  60  Hz  ±  0.2%  (battery  mode)
Overload Capacity 105%  ~  130%,  10  min  turn  to  bypass  mode;  >130%  1  s  turn  to  bypass  mode    
Phase Single  phase
Transfer Time AC  Mode  and  Battery  Mode  0  ms
Efficency ≥88%
Voltage Range 220  VAC  ±  1%
THD (lineer load) <  2%
THD (non-lineer load) <  6%
Waveform Pure  sine  wave
Battery
Battery Configuration 20x12  V  /  7  AH
Model 12  V  sealed  lead  acid  maintenance  free
DC Voltage 240  VDC
Backup Time (half load) N/A
Backup Time (full load) N/A
Charge Current (standart unit) 1  A
Charge Current (long time unit) 5  A  -  7  A
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232;  SNMP  (optional)
Environment
Noise Level <55  dB
Temperature 0℃    ~    40℃
Humidity 0%  ~  95%    (non-condensing)
Storage Temperature 0℃    ~    40℃
Operation Height <1500  m
Indication
LCD Indication 1.  Input  voltage  /  frequency,  battery  voltage,  output  voltage  /  frequency,  load  watt    /  VA    value  and  percent,  inverter  temperature
2.  Operation  mode  such  as  "on  line",  "on  batt"    or  "bypass"
LED Indication 1.  Green  LED  for  normal  operation
2.  Yellow  LED  for  warning  operation
3.  Red  LED  for  abnormal  operation
Parallel Port Parallel  availability  for  redundancy  and  load  sharing  up  to  three  units
Other
Dimension (WxDxH) mm 440x656x176
Standard Unit Net/Gross Weight N/A
Long Time Unit Net/Gross Weight 22/25  kg
Packing WxDxH (mm) 580x790x336
  Product Catalog