Products
 
Online UPS
Modular UPS
Dynamic UPS
Line Interactive UPS
Inverter
Voltage Regulator
Renewable Energy Systems
Batteries
Rectifiers
Frequency Converter
19' Rack Cabinet
Accessories
 
   
   
  Home | Products   | Powerpack Dsp 3/1 Series 10-20kVA UPS
 
3/1 Phase Online Ups, 10-15-20kVA

High frequency Double conversion On-line technology
Pure sine wave form THD< 3%
Full digitized microprocessor control
Advanced PFC technology
Wide input voltage range
UPS Start up without battery
LCD Display
Paralel operation up to 3 units
Rackmount case option
Cold start function
Advanced Battery Management
Automatic battery charge in UPS off mode
Lightning and surge protection
Short circuit and overload protection
Epo function (optional)
EMI/RFI Filter
Fan speed auto control when loads varies
Network/fax/modem surge protection
Optional extension battery pack
Battery voltage display
Load capacity display
Smart RS232 communication with monitoring software
Optional SNMP Card slot
CE, ISO9001 and TSEK certificates
   
  Technical Features
  tabmenu
Capacity VA 10  kVA  /  7  kW
Input
Voltage Range 304  ±  5  VAC  ~  478  ±  5  VAC
Frequency 46~54Hz±0.5Hz  or
56~64Hz±0.5Hz  auto  sensing
Power Factor ≥0.95
Phase Three  phase
Output
Crest Factor 3:1(max)
Short Circuit Protection 5  cycles  turn  off  inverter,  no  transfer  to  bypass,  provide  alarm  (AC  mode)
5  cycles  turn  off  inverter,  provide  alarm  (battery  mode)
input  fuse  blown  or  breaker  action  (bypass  mode)
Voltage Range 220  VAC  ±  1%
Frequency Range 50  Hz  /  60  Hz  ±  0.2%  (battery  mode)
Overload Capacity 105%~130%,  10min  turn  to  bypass  mode
>130%  1s  turn  to  bypass  mode
Phase Single  phase
Transfer Time Between  AC  Mode  and  Battery  Mode  0  ms
Between  AC  Mode  and  Bypass  Mode  0  ms
Efficency >90%
THD (lineer load) <2%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Battery
Battery Configuration 20×12  V  /  7  AH
Model 12  V  sealed  lead  acid  maintenance  free
DC Voltage 240  VDC
Backup Time (half load) 13  min
Backup Time (full load) 5  min
Charge Current (standart unit) 1  A
Charge Current (long time unit) 5  A  -  7  A
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Humidity 0%~95%  (non-condensing)
Storage Temperature 0~40  ℃
Acoustic Noise <55dB
Operation Height <1500m
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  value  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication 1.  Green  LED  for  normal  operation,
2.  Yellow  LED  for  warning  condition
3.  Red  LED  for  abnormal  operation
Parallel Port Parallel  availability  for  redundancy  and  load  sharing  up  to  three  units
Other
Dimension (WxDxH) mm 260×570×717
Standard Unit Net/Gross Weight 95/109kg
Long Time Unit Net/Gross Weight 39/51Kg
Packing WxDxH (mm) 430×700×845
Capacity VA 15  kVA  /  10.5  kW
Input
Voltage Range 304  ±  5  VAC  ~  478  ±  5  VAC
Frequency 46~54Hz±0.5Hz  or
56~64Hz±0.5Hz  auto  sensing
Power Factor ≥0.95
Phase Three  phase
Output
Crest Factor 3:1(max)
Short Circuit Protection 5  cycles  turn  off  inverter,  no  transfer  to  bypass,  provide  alarm  (AC  mode)
5  cycles  turn  off  inverter,  

provide  alarm  (battery  mode)
input  fuse  blown  or  breaker  action  (bypass  mode)
Voltage Range 220  VAC  ±  1%
Frequency Range 50  Hz  /  60  Hz  ±  0.2%  (battery  mode)
Overload Capacity 105%~130%,  10min  turn  to  bypass  mode
>130%  1s  turn  to  bypass  mode
Phase Single  phase
Transfer Time Between  AC  Mode  and  Battery  Mode  0  ms
Between  AC  Mode  and  Bypass  Mode  0  ms
Efficency >90%
THD (lineer load) <2%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Battery
Battery Configuration 20×12  V  /  7  AH
Model 12  V  sealed  lead  acid  maintenance  free
DC Voltage 240  VDC
Backup Time (half load) 13  min
Backup Time (full load) 5  min
Charge Current (standart unit) 1  A
Charge Current (long time unit) 5  A  -  7  A
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Humidity 0%~95%  (non-condensing)
Storage Temperature 0~40  ℃
Acoustic Noise <55dB
Operation Height <1500m
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  value  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication 1.  Green  LED  for  normal  operation,
2.  Yellow  LED  for  warning  condition
3.  Red  LED  for  abnormal  operation
Parallel Port Parallel  availability  for  redundancy  and  load  sharing  up  to  three  units
Other
Dimension (WxDxH) mm 320×620×950
Standard Unit Net/Gross Weight N/A
Long Time Unit Net/Gross Weight 60/74Kg
Packing WxDxH (mm) 410×717×1050
Capacity VA 20  kVA  /  14  kW
Input
Voltage Range 304  ±  5  VAC  ~  478  ±  5  VAC
Frequency 46~54Hz±0.5Hz  or
56~64Hz±0.5Hz  auto  sensing
Power Factor ≥0.95
Phase Three  phase
Output
Crest Factor 3:1(max)
Short Circuit Protection 5  cycles  turn  off  inverter,  no  transfer  to  bypass,  provide  alarm  (AC  mode)
5  cycles  turn  off  inverter,  

provide  alarm  (battery  mode)
input  fuse  blown  or  breaker  action  (bypass  mode)
Voltage Range 220  VAC  ±  1%
Frequency Range 50  Hz  /  60  Hz  ±  0.2%  (battery  mode)
Overload Capacity 105%~130%,  10min  turn  to  bypass  mode
>130%  1s  turn  to  bypass  mode
Phase Single  phase
Transfer Time Between  AC  Mode  and  Battery  Mode  0  ms
Between  AC  Mode  and  Bypass  Mode  0  ms
Efficency >90%
THD (lineer load) <2%
THD (non-lineer load) <6%
Waveform Pure  sine  wave
Battery
Battery Configuration 20×12  V  /  7  AH
Model 12  V  sealed  lead  acid  maintenance  free
DC Voltage 240  VDC
Backup Time (half load) 13  min
Backup Time (full load) 5  min
Charge Current (standart unit) 1  A
Charge Current (long time unit) 5  A  -  7  A
Recharge Time 90%  capacity  after  8  hrs  charging
Communication Interface RS232  ;  SNMP  (optional)
Environment
Humidity 0%~95%  (non-condensing)
Storage Temperature 0~40  ℃
Acoustic Noise <55dB
Operation Height <1500m
Indication
LCD Indication 1.  Input  voltage/frequency,  battery  voltage,  output  voltage/frequency,  load  watt/VA  value  and  percent,  inverter  temperature
2.  Operation  mode  such  as  “on  line”,  “on  batt”,  or  “or  bypass”
LED Indication 1.  Green  LED  for  normal  operation,
2.  Yellow  LED  for  warning  condition
3.  Red  LED  for  abnormal  operation
Parallel Port Parallel  availability  for  redundancy  and  load  sharing  up  to  three  units
Other
Dimension (WxDxH) mm 320×620×950
Standard Unit Net/Gross Weight N/A
Long Time Unit Net/Gross Weight 60/74Kg
Packing WxDxH (mm) 410×717×1050
  Product Catalog